Formulas of Motion

Linear and angular acceleration, velocity and displacement

Linear Motion Formulas

car average velocity speed

Velocity can be expressed as (velocity is constant):

v = s / t         (1a)

where

v = velocity (m/s, ft/s)

s = linear displacement (m, ft)

t = time (s)

Velocity can be expressed as (acceleration is constant):

v = v0 + a t         (1b)

where

v0 = initial linear velocity (m/s, ft/s)

a = acceleration (m/s2, ft/s2)

Linear displacement can be expressed as (acceleration is constant):

s = v0 t + 1/2 a t2         (1c)

Combining 1a and 1c to express the final velocity

v = (v02 + 2 a s)1/2         (1d)

Velocity can be expressed as (velocity is variable)

v = ds / dt (1f)

where

ds = change of displacement (m, ft)

dt = change in time (s)

Acceleration can be expressed as

a = dv / dt         (1g)

where

dv = change in velocity (m/s, ft/s)

Angular Motion Formulas

angular velocity

Angular velocity can be expressed as (angular velocity = constant):

ω = θ / t         (2a)

where

ω= angular velocity (rad/s)

θ = angular displacement (rad)

t = time (s)

Angular velocity can be expressed as (angular acceleration is constant):

ω = ωo + α t         (2b)

where

ωo = angular velocity at time zero (rad/s)

α = angular acceleration (rad/s2)

Angular displacement can be expressed as (angular acceleration is constant):

θ = ωo t + 1/2 α t2         (2c)

Combining 2a and 2c:

ω = (ωo2 + 2 α θ)1/2

Angular acceleration can be expressed as:

α = dω / dt = d2θ / dt2         (2d)

where

dθ = change of angular displacement (rad)

dt = change in time (s)

Search the Engineering ToolBox

Engineering ToolBox - SketchUp Edition - Online 3D modeling!

3D Engineering ToolBox - draw and model technical applications

Engineering ToolBox - SketchUp Edition - enabled for use with the amazing, fun and free Google SketchUp

Translate the Engineering ToolBox
About the EngineeringToolbox